Siemens Mendix SAML: 1 CVE, High 8.7
Summary
CISA reports 1 vulnerability in Siemens Mendix SAML (Mendix 10 compatible), Mendix SAML (Mendix 11 compatible), Mendix SAML (Mendix 9.24 compatible). Weakness type: Improper Verification of Cryptographic Signature. Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. Highest CVSS v3 score: 8.7 (High), exploitable over the network.
At a glance
- Vendor
- Siemens
- Products
- Mendix SAML (Mendix 10 compatible), Mendix SAML (Mendix 11 compatible), Mendix SAML (Mendix 9.24 compatible)
- CVEs
- CVE-2026-80465
- Highest CVSS v3
- 8.7 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N
- Highest CVSS v4
- –
- Known exploited (KEV)
- No CVE from this advisory is on the KEV list as of the last refresh
- Sectors (per CISA)
- Critical Manufacturing, Information Technology
- Deployed
- Worldwide
- Vendor HQ
- Germany
Vulnerabilities
| CVE | Weakness | CVSS v3 | CVSS v4 | KEV | Description (from advisory) |
|---|---|---|---|---|---|
| CVE-2026-80465 | Improper Verification of Cryptographic Signature | 8.7 | – | No | CVE-2026-80465 |
Affected products (3)
- Mendix SAML (Mendix 10 compatible) < V4.2.3
- Mendix SAML (Mendix 11 compatible) < V4.2.3
- Mendix SAML (Mendix 9.24 compatible) < V3.6.27
Vendor fixes and mitigations (from advisory)
- Vendor Fix: Update to V3.6.27 or later version link
- Vendor Fix: Update to V4.2.3 or later version link
Also apply CISA's standard ICS practices: minimize network exposure, keep control networks behind firewalls and isolated from business networks, and use up-to-date secure remote access.
Sources
- CISA advisory ICSA-26-258-06
- Machine-readable CSAF record
- https://cert-portal.siemens.com/productcert/csaf/ssa-887643.json
- https://cert-portal.siemens.com/productcert/html/ssa-887643.html
This page is generated automatically from the CISA advisory text. It is not a substitute for the vendor's guidance; verify affected versions and fixes at the source before making changes to control systems.