Advisories › IXON › ICSA-26-246-02

IXON VPN Client: 1 CVE, Critical 9.6

Critical 9.6 Oil & gas relevant ICSA-26-246-02 · Published Sep 3, 2026 · Updated Sep 9, 2026

Summary

CISA reports 1 vulnerability in IXON VPN Client. Weakness type: Improper Neutralization of CRLF Sequences ('CRLF Injection'). Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges. Highest CVSS v3 score: 9.6 (Critical), exploitable over the network.

What to do: Act now: IXON recommends updating the IXON VPN client to version 1.4.7 or later on every computer where it is installed.
Why this matters for oil & gas: IXON VPN clients are used for remote access to PLCs and HMIs.

At a glance

Vendor
IXON
Products
VPN Client
CVEs
CVE-2026-75925
Highest CVSS v3
9.6 CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
Highest CVSS v4
–
Known exploited (KEV)
No CVE from this advisory is on the KEV list as of the last refresh
Sectors (per CISA)
Commercial Facilities, Critical Manufacturing, Energy, Information Technology, Water and Wastewater
Deployed
Worldwide
Vendor HQ
Netherlands

Vulnerabilities

CVEWeaknessCVSS v3CVSS v4KEVDescription (from advisory)
CVE-2026-75925Improper Neutralization of CRLF Sequences ('CRLF Injection')9.6–NoImproper Neutralization of CRLF Sequences (CWE-93) in IXON VPN Client before version 1.4.7 allows an attacker to execute commands as root or SYSTEM. Configuration values accepted by the local service are written to a file later consumed by a privileged subprocess, without line-ending sequences being neutralised, which allows additional directives to be introduced into that file. The configuration …

Affected products (1)

Vendor fixes and mitigations (from advisory)

Also apply CISA's standard ICS practices: minimize network exposure, keep control networks behind firewalls and isolated from business networks, and use up-to-date secure remote access.